611 2 clear floor space.
Ada clear floor area.
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed.
This edition must be followed until the standards are updated to reference a later edition of the asme a17 1 code.
Door hardware ada compliant locks exit devices handles pulls latches and other operable parts on doors shall comply operable parts of such hardware shall be 34 inches minimum and 48 inches maximum above the finish floor or ground.
A clear floor or ground space complying with 305 positioned for parallel approach shall be provided.
4 13 7 two doors in series.
Platform lift clear floor space and doors gates.
A clear floor space complying with 305 positioned for a forward approach shall be provided.
Clear floor or ground space.
One full unobstructed side of the clear floor or ground space shall adjoin an accessible route or adjoin another clear floor or ground space.
Provisions for these elements apply the clear floor or ground specifications in 305.
The floor or ground area within the required clearances shall be level and clear.
Sufficient clear floor or ground space is required at accessible controls operable parts drinking fountains lavatories and sinks atms and fare machines appliances beds and other elements.
Handles pulls panic bars.
Where a single clear floor space complying with 305 positioned for parallel approach is provided between two beds a clear floor or ground.
The clear floor space shall be positioned for parallel approach to the side of the bed.
Department of justice september 15 2010 it states.
804 3 1 clear floor or ground space.
The clear floor or ground space required at elevator call buttons must remain free of obstructions including ashtrays plants and other decorative elements that prevent wheelchair users and others from reaching.
Where a clear floor or ground space is located in an alcove or otherwise confined on all or part of three sides additional maneuvering clearance shall be provided in.
The clear floor or ground space shall be centered on the kitchen work surface and shall provide knee and toe clearance complying with 306.
Advisory 407 2 1 3 clear floor or ground space.
But they must be located outside the minimum clear area specified for.
Entry doors to acute care hospital bedrooms for in patients shall be exempted from the requirement for space at the latch side of the door see dimension x in figure below if the door is at least 44 in 1120 mm wide.
Operable parts including doors lint screens and detergent and bleach compartments shall comply with 309.
Forward reach from a wheelchair is covered in section 308 2 1 of the 2010 ada standards for accessible design published by the u s.
A clear floor or ground space complying with 305 shall be provided at call controls.
Where a forward reach is unobstructed the high forward reach shall be 48 inches 1220 mm maximum and the low forward reach shall be 15 inches 380 mm minimum above the finish floor or ground.