Requirement beside the door on the latch side and so the clear space box may slide left or right as necessary in front of the door in this scenario.
Ada clear floor area latch approach.
611 2 clear floor space.
Operable parts including doors lint screens and detergent and bleach compartments shall comply with 309.
If the depth of a standard toilet stall is increased at least 3 in 75 mm then a floor mounted water closet may be used.
Sufficient clear floor or ground space is required at accessible controls operable parts drinking fountains lavatories and sinks atms and fare machines appliances beds and other elements.
The clear floor or ground space shall be centered on the appliance.
Provisions for these elements apply the clear floor or ground specifications in 305.
804 3 1 clear floor or ground space.
Entry doors to acute care hospital bedrooms for in patients shall be exempted from the requirement for space at the latch side of the door see dimension x in figure below if the door is at least 44 in 1120 mm wide.
If the latch side clearance is at least 42.
Controls for platform lifts shall comply with 309.
4 13 7 two doors in series.
The clear floor or ground space shall be centered on the kitchen work surface and shall provide knee and toe clearance complying with 306.
Clear floor space in platform lifts shall comply with 305.
The floor or ground area within the required clearances shall be level and clear.
Arrangements shown for standard toilet stalls may be reversed to allow either a left or right hand approach.
Additional stalls shall be provided in conformance with 4 22 4.
All required door clear floor spaces to have a maximum slope of 1 48 2 per cbc.
Space at least 60 deep in front of a door will accommodate a forward approach except in case of hinge approaches on the pull side.
Again this diagram does not have a min.
410 6 doors and gates.
A clear floor space complying with 305 positioned for a forward approach shall be provided.
Any ramp system that is intended for public use must comply with the americans with disabilities act ada.
410 4 platform to runway clearance.
A slide side approach to a sliding or folding door requires a clear space in front of the door measuring a min.
A clear floor or ground space complying with 305 positioned for parallel approach shall be provided.
The depth can be 54 min.
Latch approach sliding folding doors gates with latch approach use.
Latch side clearance is required if the depth is 60 min.
Ada sources 309 operable parts 404 2 manual doors doorways and manual gates 404 2 2 double leaf doors and gates.
Clear floor or ground space.
410 3 clear floor space.