Active and passive monitoring.
Active air sampling sop.
Active there are two primary methods for microbial air sampling.
In active monitoring a microbial air sampler is used to force air into or onto its collection medium e g petri dish with nutrient agar based test media over a specified period of time.
Passive air sampling passive air sampling i e settle plates is a frequently.
The organisms are then visible to the naked eyes and can be counted for an assessment of the level of contamination.
Sterilise the stainless steel aspirating head of the air sampler prior to use by autoclaving as per sop.
5 2 operation of air.
Place the axis in vertical position.
Active air sampling requires the use of a microbiology air sampler to physically draw a known volume of air over or through a particle collection device and there are two main types.
This nut will be the bottom limit.
This leaves determination of the number ofsites for passive air sampling and surface sampling.
6 1 6 place the cassette in the air sampler under an laf.
Standard operating procedures for the passive air sampling 2 2 pas assembling the pas should be assembled from the bottom to the top.
Airborne gases and vapours are collected by a physical process such as diffusion through a static air layer or permeation through a membrane.
Analyze the microbial quality of air by sampling 100 litres of air at each of the locations mentioned in annexure i using active air sampler carry the pre incubated scda plates and sterile ss head in a ss container to the sampling location.
Enter into the aseptic area following aseptic area entry and exit sop of the concerned block.
Perform the growth promotion test of each lot of media used for environmental monitoring as per sop.
Fertility test of media.
6 2 switching the sampler on.
6 2 1 push the on off button.
6 2 2 after pressing the on off button the previously selected air sample volume retained in the memory appears on the display.
Typically sampled air is drawn by a suction pump through a narrow inlet tube into a small.
5 9 5 regulate the pressure of the air so that the flow rate is in between 140l to 180l per minute.
The collected culture can then be incubated and.
1 impingers impingers use a liquid medium for particle collection.
When the pre set sampling cycle is completed the plate is removed and incubated.
5 9 7 close the media cassettes properly after sampling 5 9 8 clean the pump with 70 ipa before taking it to the next sampling location port.
At 3 cm of the end of the axis screw a nut.
5 9 6 ensure that m air t media cassette is in place before sampling is started.
Active sampling involves the use of an air sampling pump to actively pull air through a collection device such as a filter.
Carry the preincubated scda plates and sterile ss head in a ss container to the sampling location.
The following steps describe the way to assemble the passive air sampler.